Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
The Journal of Practical Medicine ; (24): 3162-3165, 2015.
Article in Chinese | WPRIM | ID: wpr-481132

ABSTRACT

Objective To investigate the clinical efficacy of umbilical blood stem cell transplantation (UCBSCT) on the treatment of hepatitis B liver cirrhosis. Methods Forty-eight patients with hepatitis B liver cirrhosis were enrolled and divided into the treatment group and the control group. There were 25 patients in the treatment group , who received UCBSCT treatment based on conventional liver protection treatment and 23 patients in the control group , who received conventional liver protection treatment. The changes of liver function , coagulation function, clinical symptoms, signs and side effects were studied before the treatment and at 2, 4, 12 and 24 weeks post-treatment. Results The levels of albumin, cholinesterase, and prothrombin activity in the treatment group were higher than those before treatment and were higher than those in the control group. The parameters in the control group were not significantly changed before and after the treatment (P > 0.05). The levels of alanine aminotransferase,aspartate aminotransferase,total bilirubin in both two groups were not significantly changed before and after the treatment (P > 0.05). After 4-week treatment,the differences on improvement of appetite , lacking in strength , abdominal distension , ascites were statistically significant in the treatment group compared with the control group (P < 0.05). No adverse reactions were observed in all groups. Conclusion UCBSCT on the treatment of hepatitis B liver cirrhosis is safe and reliable.

2.
Clinical Medicine of China ; (12): 206-211, 2015.
Article in Chinese | WPRIM | ID: wpr-460474

ABSTRACT

Objective To investigate the effects of human umbilical cord mesenchymal stem cells (hUCMSCs)transplantation on the treatment of hypoxic-ischemic encephalopathy(HIE). Methods A total of 25 HIE patients were randomly divided into stem cell transplantation group(15 case)and control group(10 cases). The patients in transplantation group were given intravenous infusion of hUCMSCs,which isolated under sterile condition in vitro and cultured, while in control group were treated with routine drug treatment. Neurological function( American National Institutes of Health Stroke Scale( NIHSS ),Barthel index (BI)),extrapyramidal function(Unified Parkinson's disease questionnaire(UPDRS)),cognition and emotional reaction(The mini mental state examination(MMSE),the 14 item Hamilton Depression Scale(HAMD14)and HAMD24)were all assessed before and after transplantation for 14 d,90 d and 180 d respectively to evaluate the clinical efficacy of hUCMSCs transplantation. Results There was no significant difference between two groups in terms of each function before transplantation. The scores of transplantation group were all obviously improved after treatment for 14 d,90 d and 180 d compared to that of before treatment,and the therapy effect in transplantation group was significantly better than that of the control group( NIHSS:Ftime =4. 372,P=0. 031;Ftime*group =4. 175,P=0. 038;Fgroup =3. 897,P=0. 045.BI:Ftime =4. 728,P=0. 044;Ftime*group =4. 894,P=0. 037;Fgroup =4. 284,P=0. 039.UPDRS:Ftime =5. 112,P=0. 047;Ftime*group =4. 895,P=0. 045;Fgroup=3. 879,P =0. 031.MMSE:Ftime =5. 135,P =0. 039;Ftime*group =3. 213,P =0. 036;Fgroup =4. 184,P=0. 045.HAMD14:Ftime =3. 977,P =0. 049;Ftime*group =4. 587,P =0. 038;Fgroup =4. 381,P =0. 041.HAMD24:Ftime =3. 845,P =0. 033;Ftime*group =4. 125,P=0. 035;Fgroup =3. 547,P=0. 034). Conclusion Transplantation of hUCMSCs is safe and effective for treatment of HIE,which can significantly improve the neurological function,extrapyramidal function,cognition and emotion.

3.
Chinese Journal of Tissue Engineering Research ; (53): 974-978, 2014.
Article in Chinese | WPRIM | ID: wpr-445384

ABSTRACT

BACKGROUND:Currently, neural stem celltransplantation can be performed through three main approaches:local lesions, blood circulation, and cerebrospinal fluid. OBJECTIVE:To review the transplantation of neural stem cells or neural precursor cells via the cerebrospinal fluid in the treatment of central nervous system diseases. METHODS:A computer-based search of PubMed and CHKD databases was performed to retrieve articles concerning transplantation of neural stem cells via the cerebrospinal fluid, and its application and therapeutic mechanism in the treatment of central nervous system diseases in both animal experiment and clinic study published from 2000 to 2009. RESULTS AND CONCLUSION:It is suitable for neural stem cellsurvival, proliferation, and differentiation in the cerebrospinal fluid. Transplantation of neural stem cells via the cerebrospinal fluid is effective and feasible to treat central nervous system diseases. However, some problems have not been solved, such as the source of neural stem cells, the optimal time window and celldose, the safety and the long-term effect. Further studies are needed to pave the way for the intrathecal injection of neural stem cells in the treatment of central nervous system diseases.

4.
Chinese Journal of Tissue Engineering Research ; (53): 2591-2595, 2008.
Article in Chinese | WPRIM | ID: wpr-407183

ABSTRACT

BACKGROUND: It is difficult to cover aneurysm-like ventricular septal defect (VSD) of large inlet and multiple outlets completely with symmetrical type occluders or eccentric type occluders. OBJECTIVE: To investigate the feasibility of A4B2 occluder devices for covering aneurysm-like VSD, and to observe the effects of proper occhiders selected according to pseudoaneurysm size on coveting aneurysm-like VSD. DESIGN: Case analysis.SETTING: the First Hospital of Hebei Medical University. PARTICIPANTS: From August 2004 to May 2006, 226 patients with the pseudoaneurysm of petimembranous VSD, who underwent interventional therapy in the First Hospital of Hehei Medical University, were recruited in the study. According to the results of the left ventricular angiography, 36 patients of pseudoaneurysm of petimembranous VSD with large inlet and multiple outlets were closured with A4B2 occluder devices. According to the results of the left ventricular angiography, the mean diameter of the left inlet of VSD was (10.6+8.7) mm (ranged from 8 to 21 mm), the mean diameter of the right outlet of VSD was (3.1 ± 2.9) mm (ranged from 2 to 8 ram). Main materials: Occluder device and delivery mechanism were offered by Shanghai Shape Memory Alloy Materials Company and Beijing Starway Medical Technology Inc. They were processed into double disks using nickel-titanium shape memory alloy wires by a special technology to close VSD by a transcatheter approach. The size of the occluder was denoted with the diameter of the waist, and the Size ranged from 4 to 16 mm in the present study. METHODS: All the occluders were transferred by a 7-10 F transferring sheath from right heart system, and the mean diameter of the occluders was (6.364-2.48) nun (ranged from 4 to 16 ram). Fifteen minutes after the procedure, left ventricular angiography and transthoracic echocardiography (TIE) were performed again to evaluate the efficacy. After the procedure, electrocardiogram (ECG) monitoring lasted for 5 successive days in all patients, and ECG and TIE were performed 1, 3, 6 and 12 months later. MAIN OUTCOME MEASURES: Residual shunt, arrhythmia and valve function as well as blood compatibility. RESULTS: Sixteen cases were closured by placing the occhiders into left inlet of VSD, 16 cases were closured by placing the occluders into the pseudoaneurysm completely, and 4 cases were closured at the outlet of the defects. The results of the left ventricular angiography and TTE that performed fifteen minutes after the procedure demonstrated that 32 cases were completely closured and slightly residual shunts (< 3 mm) was found in other 4 patients. And confirmed by TIE, the residual shunts completely disappeared in 2 of the 3 patients 24 hours later while in the other one in 1 month after the procedure. Temporary left bundle branch block was found in 3 cases while temporary right bundle branch block was found in 2 cases, and all of them recovered within one week. Without severe complications, all of the 36 patients were treated successfully with A4B2 (thin waist shape) occluder devices made in China. Critical appraisal in blood compatibility of the implantation materials used in this research had been performed. The hemolysis ratio was less than 5%, the platelet adhesion was less, and the blood coagulation function ,the immune system response( immunoglobulin and complement)and the re-endothelialization of material surface were all normal. CONCLUSION: Transcatheter interventional therapy with domestic A4B2 occluder devices for VSD with pseudoaneurysm is safe, effective, promising, and has fewer complications. The key to the procedure is to select suitable occluders and suitable positions where to plant them according to the size, morphologic characteristics, position, and maturity of the pseudoaneurysm.

SELECTION OF CITATIONS
SEARCH DETAIL